This fence and wall standards (FW) section applies to the following zoning district:
MP

The following standards shall apply:

A. Height.

1. Perimeter Fences. Fences and walls around the perimeter of a manufactured home park shall not exceed four (4) feet in height when installed along a frontage street and six (6) feet in height with located within ten (10) feet of the property line.

2. Dwelling Site Fences. Decorative fences up to three and one-half (3½) feet in height are allowed on a dwelling site, but they shall not enclose, partially enclose, or give the perception of being an enclosed dwelling site.

B. Height Exceptions. Fences that surround a community swimming pool or sport court located within the building setbacks, and at least fifty (50) feet from the public right-of-way of a perimeter street, are allowed up to eight (8) feet in height.

C. Types.

1. Permitted Materials in Front and Side Yards. Wood, composite outdoor wood, stone, masonry, wrought iron, and decorative metal shall be permitted fence and wall materials.

2. Permitted Materials in Rear Yards. Vinyl, zinc or powder coated chain link, wood, composite outdoor wood, stone, masonry, wrought iron, and decorative metal shall be permitted fence and wall materials.

3. Prohibited Material. Fences and walls shall not incorporate metal or plastic slats in chain link fences; and barbed wire, above ground electrified wires, razor wire, broken glass, sharpened top spikes, or similarly hazardous fence material are prohibited. [Ord. 12-27-11 § 5.30.]